The reactivation of geological faults can be triggered by stress changes due to fluid injection affecting their permeability and potentially transforming them into preferential flow channels. This can impact reservoir production dynamics and compromise fluid storage safety. This study assesses the feasibility of long-term CO2 storage in a geological reservoir in the Campos Basin, Rio de Janeiro, Brazil, focusing on fault system structural integrity vital in preventing leakage and ensuring storag